PRODUCT

+
  • Product

-100℃ ± 100℃

-100℃ ± 100℃

The low-temperature coolant circulation refrigerator is an experimental study that achieves low-temperature environment through the cooling cycle of water and other media. The low-temperature coolant circulation pump is composed of water air contact, contact heat dissipation, evaporation heat dissipation, and radiation heat dissipation

产品描述

Functional characteristics of high and low temperature integrated machine:

1. The pre cooling device, refrigeration system, and heating system can be used in combination
2. It has various protection functions such as high and low voltage protection, overload protection, overcurrent protection, and grounding protection
3. The cooling rate is fast and can be forced to cool down quickly
4. The refrigeration system compressor, oil separator, solenoid valve, expansion valve, etc. are all imported brands. The evaporator is a fully brazed plate heat exchanger. Real time monitoring of 9 liquid level pipes can avoid the lack of heat carrying fluid.
5. The circulation system adopts a closed type, non volatile, and protects the health of the experimenter
6. The storage tank and circulation pipeline are made of 304 stainless steel, with good corrosion resistance
7. The entire machine is stable and reliable, and can operate continuously for a long time
8. The shell adopts electrostatic plastic spraying SPCC, which has good anti-corrosion effect
9. Used in conjunction with reaction kettles such as 20L, 50L, and 100L, to cool the materials inside the reactor to -25° C. It can also be heated to 200° C。

  • 产品描述
  • Product features
  • Performance
  • Device video
  • dotIntroduce

    Functional characteristics of high and low temperature integrated machine:

    1. The pre cooling device, refrigeration system, and heating system can be used in combination
    2. It has various protection functions such as high and low voltage protection, overload protection, overcurrent protection, and grounding protection
    3. The cooling rate is fast and can be forced to cool down quickly
    4. The refrigeration system compressor, oil separator, solenoid valve, expansion valve, etc. are all imported brands. The evaporator is a fully brazed plate heat exchanger. Real time monitoring of 9 liquid level pipes can avoid the lack of heat carrying fluid.
    5. The circulation system adopts a closed type, non volatile, and protects the health of the experimenter
    6. The storage tank and circulation pipeline are made of 304 stainless steel, with good corrosion resistance
    7. The entire machine is stable and reliable, and can operate continuously for a long time
    8. The shell adopts electrostatic plastic spraying SPCC, which has good anti-corrosion effect
    9. Used in conjunction with reaction kettles such as 20L, 50L, and 100L, to cool the materials inside the reactor to -25° C. It can also be heated to 200° C。

  • The low-temperature coolant circulation refrigerator is an experimental study that achieves low-temperature environment through the cooling cycle of water and other media. The low-temperature coolant circulation pump is composed of water air contact, contact heat dissipation, evaporation heat dissipation, and radiation heat dissipation. The low-temperature cooling ring refrigerator is an experimental study that achieves low-temperature environment through the cooling cycle of water and other media. The low-temperature coolant circulation pump is composed of water air contact, contact heat dissipation, evaporation heat dissipation, and radiation heat dissipation. Experimental research on the low-temperature environment achieved through the cooling cycle of water and other media in a low-temperature coolant circulation refrigeration machine. The low-temperature coolant circulation pump is composed of water air contact, contact heat dissipation, evaporation heat dissipation, and radiation heat dissipation.

  • model

    DLSB-500/80

    DLSB-1000/80

    DLSB-1500/80

    DLSB-2000/80

    DLSB-3000/80

    Main technical parameters

    Scope of use

    -80℃~ordinary temperature;±1℃

    ambient temperature(℃)

    ≤30℃

    Optimal environmental humidity

    60%

    voltage(V)

    220/380/460

    380/460

    Phase number(P)

    15

    20

    25

    30

    40

    frequency(Hz)

    50/60 be current

    total power(Kw)

    23.5

    32

    39

    39

    61

    Refrigeration capacity(w)

    25℃

    N/A

    N/A

    N/A

    N/A

    N/A

    5℃

    N/A

    N/A

    N/A

    N/A

    N/A

    0℃

    72700

    98000

    112000

    135000

    180000

    -10℃

    51900

    75000

    96000

    110000

    165000

    -30℃

    42050

    56000

    74000

    95000

    137000

    -40℃

    N/A

    N/A

    N/A

    N/A

    N/A

    -60℃

    29000

    34000

    43000

    69000

    95000

    -80℃

    6430

    8100

    12000

    18000

    20000

    temperature sensor

    PT100

    Protect

    Overvoltage, delay, overcurrent, overheating, leakage, protector

    compressor

    types of

    Semi enclosed type

    brand

    Refcomp

    power(Kw)

    22.5

    30

    37.5

    45

    60

    current(A)

    45

    60

    75

    90

    120

    P

    15

    20

    25

    30

    40

    number

    2

    refrigerant

    R404A R23

    condenser

    types of

    forced air cooling

    Fan type

    YWF

    Number of fans

    2

    evaporator

    types of

    Plate heat exchange

    Tank volume(L)

    300

    400

    400

    500

    700

    Refrigerant flow rate(L/min)

    180

    External circulation nozzle size(DN)

    32

    40

    circulating pump

    types of

    canned-motor pump

    brand

    LEAN

    power(w)

    750

    current(A)

    1.5

    rated head(m)

    15

    Rated flow rate(L/min)

    180

    *PLC

    control system

    Siemens S7-200smartPLC

    Programming

    Can write 5 programs, each with up to 40 steps

    control model

    The material temperature and equipment outlet temperature can be switched independently

    Communication protocol

    Modbus RTU protocol RS485 interface (optional RS232 Ethernet)

    operation panel

    7-inch Siemens color touch screen (optional 10 inch)

    data export

    Support for USB data export, can export temperature data in TXT format

    packing list

    Two sets of adaptive valves, one roll of Thread seal tape

    2 stainless steel insulated hoses

    One operating manual

    The data section is factory test data, but there may be some slight deviation in reality

    *PLC is an optional PLC part of the data, and if there is no PLC, it is not applicable


  • 产品描述
  • Product features
  • Performance
  • Device video
  • Functional characteristics of high and low temperature integrated machine:

    1. The pre cooling device, refrigeration system, and heating system can be used in combination
    2. It has various protection functions such as high and low voltage protection, overload protection, overcurrent protection, and grounding protection
    3. The cooling rate is fast and can be forced to cool down quickly
    4. The refrigeration system compressor, oil separator, solenoid valve, expansion valve, etc. are all imported brands. The evaporator is a fully brazed plate heat exchanger. Real time monitoring of 9 liquid level pipes can avoid the lack of heat carrying fluid.
    5. The circulation system adopts a closed type, non volatile, and protects the health of the experimenter
    6. The storage tank and circulation pipeline are made of 304 stainless steel, with good corrosion resistance
    7. The entire machine is stable and reliable, and can operate continuously for a long time
    8. The shell adopts electrostatic plastic spraying SPCC, which has good anti-corrosion effect
    9. Used in conjunction with reaction kettles such as 20L, 50L, and 100L, to cool the materials inside the reactor to -25° C. It can also be heated to 200° C。

  • dotFeatures

    The low-temperature coolant circulation refrigerator is an experimental study that achieves low-temperature environment through the cooling cycle of water and other media. The low-temperature coolant circulation pump is composed of water air contact, contact heat dissipation, evaporation heat dissipation, and radiation heat dissipation. The low-temperature cooling ring refrigerator is an experimental study that achieves low-temperature environment through the cooling cycle of water and other media. The low-temperature coolant circulation pump is composed of water air contact, contact heat dissipation, evaporation heat dissipation, and radiation heat dissipation. Experimental research on the low-temperature environment achieved through the cooling cycle of water and other media in a low-temperature coolant circulation refrigeration machine. The low-temperature coolant circulation pump is composed of water air contact, contact heat dissipation, evaporation heat dissipation, and radiation heat dissipation.

  • dotFeatures

    model

    DLSB-500/80

    DLSB-1000/80

    DLSB-1500/80

    DLSB-2000/80

    DLSB-3000/80

    Main technical parameters

    Scope of use

    -80℃~ordinary temperature;±1℃

    ambient temperature(℃)

    ≤30℃

    Optimal environmental humidity

    60%

    voltage(V)

    220/380/460

    380/460

    Phase number(P)

    15

    20

    25

    30

    40

    frequency(Hz)

    50/60 be current

    total power(Kw)

    23.5

    32

    39

    39

    61

    Refrigeration capacity(w)

    25℃

    N/A

    N/A

    N/A

    N/A

    N/A

    5℃

    N/A

    N/A

    N/A

    N/A

    N/A

    0℃

    72700

    98000

    112000

    135000

    180000

    -10℃

    51900

    75000

    96000

    110000

    165000

    -30℃

    42050

    56000

    74000

    95000

    137000

    -40℃

    N/A

    N/A

    N/A

    N/A

    N/A

    -60℃

    29000

    34000

    43000

    69000

    95000

    -80℃

    6430

    8100

    12000

    18000

    20000

    temperature sensor

    PT100

    Protect

    Overvoltage, delay, overcurrent, overheating, leakage, protector

    compressor

    types of

    Semi enclosed type

    brand

    Refcomp

    power(Kw)

    22.5

    30

    37.5

    45

    60

    current(A)

    45

    60

    75

    90

    120

    P

    15

    20

    25

    30

    40

    number

    2

    refrigerant

    R404A R23

    condenser

    types of

    forced air cooling

    Fan type

    YWF

    Number of fans

    2

    evaporator

    types of

    Plate heat exchange

    Tank volume(L)

    300

    400

    400

    500

    700

    Refrigerant flow rate(L/min)

    180

    External circulation nozzle size(DN)

    32

    40

    circulating pump

    types of

    canned-motor pump

    brand

    LEAN

    power(w)

    750

    current(A)

    1.5

    rated head(m)

    15

    Rated flow rate(L/min)

    180

    *PLC

    control system

    Siemens S7-200smartPLC

    Programming

    Can write 5 programs, each with up to 40 steps

    control model

    The material temperature and equipment outlet temperature can be switched independently

    Communication protocol

    Modbus RTU protocol RS485 interface (optional RS232 Ethernet)

    operation panel

    7-inch Siemens color touch screen (optional 10 inch)

    data export

    Support for USB data export, can export temperature data in TXT format

    packing list

    Two sets of adaptive valves, one roll of Thread seal tape

    2 stainless steel insulated hoses

    One operating manual

    The data section is factory test data, but there may be some slight deviation in reality

    *PLC is an optional PLC part of the data, and if there is no PLC, it is not applicable

  • dotFeatures

  • 产品描述
  • Product features
  • Performance
  • Device video
  • Functional characteristics of high and low temperature integrated machine:

    1. The pre cooling device, refrigeration system, and heating system can be used in combination
    2. It has various protection functions such as high and low voltage protection, overload protection, overcurrent protection, and grounding protection
    3. The cooling rate is fast and can be forced to cool down quickly
    4. The refrigeration system compressor, oil separator, solenoid valve, expansion valve, etc. are all imported brands. The evaporator is a fully brazed plate heat exchanger. Real time monitoring of 9 liquid level pipes can avoid the lack of heat carrying fluid.
    5. The circulation system adopts a closed type, non volatile, and protects the health of the experimenter
    6. The storage tank and circulation pipeline are made of 304 stainless steel, with good corrosion resistance
    7. The entire machine is stable and reliable, and can operate continuously for a long time
    8. The shell adopts electrostatic plastic spraying SPCC, which has good anti-corrosion effect
    9. Used in conjunction with reaction kettles such as 20L, 50L, and 100L, to cool the materials inside the reactor to -25° C. It can also be heated to 200° C。

  • dotPerformance

    The low-temperature coolant circulation refrigerator is an experimental study that achieves low-temperature environment through the cooling cycle of water and other media. The low-temperature coolant circulation pump is composed of water air contact, contact heat dissipation, evaporation heat dissipation, and radiation heat dissipation. The low-temperature cooling ring refrigerator is an experimental study that achieves low-temperature environment through the cooling cycle of water and other media. The low-temperature coolant circulation pump is composed of water air contact, contact heat dissipation, evaporation heat dissipation, and radiation heat dissipation. Experimental research on the low-temperature environment achieved through the cooling cycle of water and other media in a low-temperature coolant circulation refrigeration machine. The low-temperature coolant circulation pump is composed of water air contact, contact heat dissipation, evaporation heat dissipation, and radiation heat dissipation.

  • dotPerformance

    model

    DLSB-500/80

    DLSB-1000/80

    DLSB-1500/80

    DLSB-2000/80

    DLSB-3000/80

    Main technical parameters

    Scope of use

    -80℃~ordinary temperature;±1℃

    ambient temperature(℃)

    ≤30℃

    Optimal environmental humidity

    60%

    voltage(V)

    220/380/460

    380/460

    Phase number(P)

    15

    20

    25

    30

    40

    frequency(Hz)

    50/60 be current

    total power(Kw)

    23.5

    32

    39

    39

    61

    Refrigeration capacity(w)

    25℃

    N/A

    N/A

    N/A

    N/A

    N/A

    5℃

    N/A

    N/A

    N/A

    N/A

    N/A

    0℃

    72700

    98000

    112000

    135000

    180000

    -10℃

    51900

    75000

    96000

    110000

    165000

    -30℃

    42050

    56000

    74000

    95000

    137000

    -40℃

    N/A

    N/A

    N/A

    N/A

    N/A

    -60℃

    29000

    34000

    43000

    69000

    95000

    -80℃

    6430

    8100

    12000

    18000

    20000

    temperature sensor

    PT100

    Protect

    Overvoltage, delay, overcurrent, overheating, leakage, protector

    compressor

    types of

    Semi enclosed type

    brand

    Refcomp

    power(Kw)

    22.5

    30

    37.5

    45

    60

    current(A)

    45

    60

    75

    90

    120

    P

    15

    20

    25

    30

    40

    number

    2

    refrigerant

    R404A R23

    condenser

    types of

    forced air cooling

    Fan type

    YWF

    Number of fans

    2

    evaporator

    types of

    Plate heat exchange

    Tank volume(L)

    300

    400

    400

    500

    700

    Refrigerant flow rate(L/min)

    180

    External circulation nozzle size(DN)

    32

    40

    circulating pump

    types of

    canned-motor pump

    brand

    LEAN

    power(w)

    750

    current(A)

    1.5

    rated head(m)

    15

    Rated flow rate(L/min)

    180

    *PLC

    control system

    Siemens S7-200smartPLC

    Programming

    Can write 5 programs, each with up to 40 steps

    control model

    The material temperature and equipment outlet temperature can be switched independently

    Communication protocol

    Modbus RTU protocol RS485 interface (optional RS232 Ethernet)

    operation panel

    7-inch Siemens color touch screen (optional 10 inch)

    data export

    Support for USB data export, can export temperature data in TXT format

    packing list

    Two sets of adaptive valves, one roll of Thread seal tape

    2 stainless steel insulated hoses

    One operating manual

    The data section is factory test data, but there may be some slight deviation in reality

    *PLC is an optional PLC part of the data, and if there is no PLC, it is not applicable

  • dotPerformance
  • 产品描述
  • Product features
  • Performance
  • Device video
  • Functional characteristics of high and low temperature integrated machine:

    1. The pre cooling device, refrigeration system, and heating system can be used in combination
    2. It has various protection functions such as high and low voltage protection, overload protection, overcurrent protection, and grounding protection
    3. The cooling rate is fast and can be forced to cool down quickly
    4. The refrigeration system compressor, oil separator, solenoid valve, expansion valve, etc. are all imported brands. The evaporator is a fully brazed plate heat exchanger. Real time monitoring of 9 liquid level pipes can avoid the lack of heat carrying fluid.
    5. The circulation system adopts a closed type, non volatile, and protects the health of the experimenter
    6. The storage tank and circulation pipeline are made of 304 stainless steel, with good corrosion resistance
    7. The entire machine is stable and reliable, and can operate continuously for a long time
    8. The shell adopts electrostatic plastic spraying SPCC, which has good anti-corrosion effect
    9. Used in conjunction with reaction kettles such as 20L, 50L, and 100L, to cool the materials inside the reactor to -25° C. It can also be heated to 200° C。

  • dotVideo

    The low-temperature coolant circulation refrigerator is an experimental study that achieves low-temperature environment through the cooling cycle of water and other media. The low-temperature coolant circulation pump is composed of water air contact, contact heat dissipation, evaporation heat dissipation, and radiation heat dissipation. The low-temperature cooling ring refrigerator is an experimental study that achieves low-temperature environment through the cooling cycle of water and other media. The low-temperature coolant circulation pump is composed of water air contact, contact heat dissipation, evaporation heat dissipation, and radiation heat dissipation. Experimental research on the low-temperature environment achieved through the cooling cycle of water and other media in a low-temperature coolant circulation refrigeration machine. The low-temperature coolant circulation pump is composed of water air contact, contact heat dissipation, evaporation heat dissipation, and radiation heat dissipation.

  • dotVideo

    model

    DLSB-500/80

    DLSB-1000/80

    DLSB-1500/80

    DLSB-2000/80

    DLSB-3000/80

    Main technical parameters

    Scope of use

    -80℃~ordinary temperature;±1℃

    ambient temperature(℃)

    ≤30℃

    Optimal environmental humidity

    60%

    voltage(V)

    220/380/460

    380/460

    Phase number(P)

    15

    20

    25

    30

    40

    frequency(Hz)

    50/60 be current

    total power(Kw)

    23.5

    32

    39

    39

    61

    Refrigeration capacity(w)

    25℃

    N/A

    N/A

    N/A

    N/A

    N/A

    5℃

    N/A

    N/A

    N/A

    N/A

    N/A

    0℃

    72700

    98000

    112000

    135000

    180000

    -10℃

    51900

    75000

    96000

    110000

    165000

    -30℃

    42050

    56000

    74000

    95000

    137000

    -40℃

    N/A

    N/A

    N/A

    N/A

    N/A

    -60℃

    29000

    34000

    43000

    69000

    95000

    -80℃

    6430

    8100

    12000

    18000

    20000

    temperature sensor

    PT100

    Protect

    Overvoltage, delay, overcurrent, overheating, leakage, protector

    compressor

    types of

    Semi enclosed type

    brand

    Refcomp

    power(Kw)

    22.5

    30

    37.5

    45

    60

    current(A)

    45

    60

    75

    90

    120

    P

    15

    20

    25

    30

    40

    number

    2

    refrigerant

    R404A R23

    condenser

    types of

    forced air cooling

    Fan type

    YWF

    Number of fans

    2

    evaporator

    types of

    Plate heat exchange

    Tank volume(L)

    300

    400

    400

    500

    700

    Refrigerant flow rate(L/min)

    180

    External circulation nozzle size(DN)

    32

    40

    circulating pump

    types of

    canned-motor pump

    brand

    LEAN

    power(w)

    750

    current(A)

    1.5

    rated head(m)

    15

    Rated flow rate(L/min)

    180

    *PLC

    control system

    Siemens S7-200smartPLC

    Programming

    Can write 5 programs, each with up to 40 steps

    control model

    The material temperature and equipment outlet temperature can be switched independently

    Communication protocol

    Modbus RTU protocol RS485 interface (optional RS232 Ethernet)

    operation panel

    7-inch Siemens color touch screen (optional 10 inch)

    data export

    Support for USB data export, can export temperature data in TXT format

    packing list

    Two sets of adaptive valves, one roll of Thread seal tape

    2 stainless steel insulated hoses

    One operating manual

    The data section is factory test data, but there may be some slight deviation in reality

    *PLC is an optional PLC part of the data, and if there is no PLC, it is not applicable

  • dotVideo
视频标题

refrigeration system

Messageboard

Want a senior engineer to design a production plan for you? Want to obtain a discounted quotation for a complete set of equipment?
Please leave a message and our professional manager will immediately start providing you with one-on-one service!

Security verification

*Don't worry about information leakage, we will provide information confidentiality services for customers!

Cases